Description
Zur Ausfilterung von festen Verunreinigungen größer 3 µm und zur Feuchtigkeitsabscheidung.
Zum Vorschalten vor Mikrofilter oder vor die Kombination Mikro-/Aktivkohlefilter.
Features
| a | 118 mm |
|---|---|
| A | 118,0 mm |
| Anzeigebereich des Differenzdruckmanometers max. | 2 bar |
| Anzeigebereich des Differenzdruckmanometers min. | 0 bar |
| B1 | 907.5 mm |
| B2 | 810 mm |
| C | 72 mm |
| D | 1238 mm |
| Durchfluss | 13000 l/min |
| Durchflusswertmessung | bei P<sub>1</sub> = 6 bar und Druckabfall ?<sub>p</sub> = 0,5% |
| Eingangsdruck max. | 16 bar |
| Eingangsdruck min. | 4 bar |
| Filterbehälter | Aluminium |
| Filterelement | Polyethylen (mit 45% Hohlvolumen) |
| Filterfeinheit | 2 µm |
| Gehäuse | Aluminium |
| Gewinde | G 2 |
| Mediumstemperatur max. | 60 °C |
| Mediumstemperatur min. | 5 °C |
| Partikelabscheidung | ab 2 µm |
| Umgebungstemperatur max. | 60 °C |
| Umgebungstemperatur min. | 5 °C |
| Wirkungsgrad | 99,99 % |
| Zolltarifnummer | 84213925 |
Manufacturer
Riegler & Co. KG
Schützenstr. 27-29
72574 Bad Urach
07125/9497-0
www.riegler.de
info@riegler.de
Safety regulations
General safety instructions
• All electrical connections must be made by an authorized electrician
• Machines may only be operated with functioning safety devices
• Only allow trained personnel to operate the machine
• Maintenance and repair work may only be carried out by trained personnel
• Never work under the influence of illnesses that impair concentration, medication, drugs or alcohol
• Machines must always be disconnected from the power supply before maintenance or repair work
• Wear tight-fitting clothing and remove all objects that could cause you to get caught in machines.
• Use original spare parts and accessories
• Keep body parts away from moving parts of the machines.
• In the event of a malfunction or unusual behavior, operation must be stopped immediately until the cause has been clarified and the error has been rectified.
• Avoid overloading machines. Always work within the permitted performance range (technical data)
• Always ensure that no one is in the danger areas of the machines.
• Before using the machines, make sure that the safety devices are working properly
• Read the operating instructions and familiarize yourself with the safety devices.
• Keep the work area clean and tidy to minimize sources of danger
• Do not make any changes to machines
• Wear hearing protection to protect your hearing
• Wear appropriate safety gloves when handling chemicals or sharp objects
• Wear appropriate safety shoes to protect your feet
• Wear appropriate safety clothing
• Always observe and follow all safety instructions that are attached to the product or included with the product.